• EcoWater Systems Conditioner with Remote (ECR) EcoWater Systems Refiner with Remote (ERR) SERIES 3500 & 3502 Systems Tested and Certified by NSF Interna- ERR 3500R20 & ERR 3502R30 are Tested tional and WQA against NSF/ANSI Standard and Certified by WQA against NSF/ANSI 44 for water softening performance and the Standard 42 for chlorine taste and odor. • Consult the dealer or an experienced radio/TV tech- Use care when handling the EcoWater Systems condi- nician for help. Do not turn upside down, drop, or set on Changes or modifications not expressly approved by sharp protrusions. • Your local dealer will provide details regarding this warranty or writing within 30 days from the expiration of these guar- will refer you to the factory for additional information. In addition, the 3500 SERIES antees upon EcoWater Systems LLC, P.O.
Adobe acrobat xi pro crack patch serial key free download. WQA against NSF/ANSI Standard 44 for softener perfor. The EcoWater Systems conditioner requires a minimum water flow of 3 gallons per minute at the inlet.
• OTHER REQUIREMENTS STANDPIPE LAUNDRY TUB A drain is needed for recharge discharge water. A floor drain is preferred, close to the EcoWater Systems con- FIG. 1B ditioner/refiner. A laundry tub, standpipe, etc., are other options (See Figure 1B). NOTE: The Commonwealth of Massachusetts plumbing A 120V, 60 Hz, grounded, continuously “live”.
• TUBES cover, bag(s) of small parts needed to assemble and install a. If installing an EcoWater Systems Bypass Valve, put the unit, plus this manual, in the other. Lubricated o-ring seals onto both bypass valve ports (See EcoWater Systems conditioner/refiner models R20, R30 and Figure 3B). • (See Figure 4A).
3 - - Valve Bypass BYPASS INLET OUTLET VALVE VALVE VALVE nozzle & venturi EcoWater Systems Bypass Valve ground clamp o- -ring from conditioner/ brine to conditioner/ refiner elbow PULL OUT. • Fully open two or more conditioned cold water faucets nearby the EcoWater Systems conditioner/refiner. Care is taken at the factory to keep your EcoWater Systems conditioner/refiner clean and sanitary. However, during ship- b.
Place the bypass valve(s) in bypass position (See ping, storage, installing and operating, bacteria could get into Figure 6). • SETUP PROCEDURE electronic control compensates automatically after you set the iron level in Step 11, below. When the EcoWater Systems conditioner/refiner is plugged in for the first time, a beep sounds and the dis- 8. Press the SELECT ( ) button. • S Y S T E M S CONDITIONER/REFINER STATUS SCREENS MAIN MENU During normal operation, the EcoWater Systems condi- tioner/refiner’s display shows up to four status screens (Page 14 explains how individual screens can be turned on or off).
Advanced engineering mathematics by jain and iyengar pdf free download. Jain And Iyengar Advanced Engineering Mathematics Advanced Engineering Mathematics By Jain And Iyengar Advanced Engineering Mathematics By Jain And Iyengar 20963 Advanced Engineering Mathematics R K Jain Pdf Advanced Engineering Mathematics R.k Jain 4th Edition Solutions Manual Engineering Mathematics 4 By T.k.v.iyengar Download: Engineering. Advanced Engineering Mathematics Alpha Science International Ltd. Pangbourne England. JAIN New Delhi S.R.K. IYENGAR October 2001. Preface Contents vii 10 1. How can I get a free PDF download of Advanced Engineering Mathematics by R.K. How do I download Advance Level Engineering Mathematics 4th edition by RK Jain? How is the book 'Advanced Engineering Mathematics' by Jain and Iyengar compared to Kreyszig's book?
Each is shown for six seconds, in a rolling sequence (See Figure 15). • ECOWATER Conditioner/Refiner Operation S Y S T E M S CONNECTING TO REMOTE When the conditioner/refiner’s electronic control is first powered up, it is not yet in communication with the remote. Do the following to establish a link between FIG. 19 the two: 1.